14.1.1 Replacing a Power Supply Unit
If a power unit fails, the front orange ID LED blinks in the system unit operator 
panel. The defective power unit can be replaced while the base unit is still 
running.
V
CAUTION
Do not, under any circumstances, remove a fan module if a power 
supply unit fails!
The 2100 W power supply unit is not downwardly compatible. It may only 
be used in the S2 variant of the PRIMERGY BX600 base unit.
If a system fault occurs and the front ID LED/fault LED blinks, the fault 
must be remedied before additional components can be removed or 
added.
To ensure continuous air circulation through the chassis, the slots for the 
power supply units must not be left empty and/or open for more than five 
minutes when the system is running. Components may be damaged if 
this five minute limit is exceeded.
Ê
Check the FAN LED of the power supply units on the back of the system (see 
) to determine which power supply unit is defective.
Ê
First disconnect the power supply cable of the defective PSU from the 
mains.
Ê
Remove the power supply cable from the insulated socket of the defective 
PSU.
V
CAUTION!
Be careful! The PSU can be very hot!