Fujitsu BX600 S2 User Manual

Page of 173
PRIMERGY BX600 S2 Basic Unit
 159
Troubleshooting and Tips
Floppy Disk Cannot Be Read/Written
16.8
Floppy Disk Cannot Be Read/Written
Ê
Check whether the write protection of the floppy disk is activated.
Ê
Check the entry for the floppy disk drive in the BIOS Setup for the corre-
sponding server blade.
Ê
Check the BIOS Setup for the corresponding server blade to see whether 
the floppy disk drive controller and write permission are enabled.
16.9
Time and Date Are Not Correct
Ê
Set the time and/or date in the operating system or in the BIOS Setup for the 
corresponding server blade.
I
If the time and date are repeatedly wrong when you switch on your server 
blade, you must change the lithium battery (see the manual for the 
relevant server blade type).
16.10 Server Blade Does Not Boot
The server blade does not boot after a defective hard disk drive has been 
replaced
Incorrect SCSI configuration (onboard SCSI HostRAID controller)
Ê
In the SCSI configuration menu, check the settings for the hard disk drives 
(SCSI Device Configuration) and the additional settings (Advanced Config-
uration Options).
16.11 Defective Drive
Drives are identified as dead on system start
The configuration of the RAID controller is wrong.
Ê
Check and correct the settings for the drives using the utility for the RAID 
controller.
For more details, see the manual for the RAID controller (on the ServerBooks 
CD under the heading “Controllers”).