Fujitsu BX600 S2 User Manual

Page of 173
PRIMERGY BX600 S2 Basic Unit
 23
Important Notes
Notes on Safety
Make sure that the PRIMERGY BX600 S2 basic unit is connected to 
the mains for at least one minute before pressing the power ON/OFF 
button to switch the system ON.
V
CAUTION!
The server automatically adjusts to a mains voltage of 200 - 240 V. 
The server may only be put into operation if the mains voltage range 
set on the server corresponds to the local mains voltage.
This device has safety-tested power cables and must only be 
connected to properly grounded power sockets or CEE sockets.
The power button does not disconnect the device from the mains 
voltage. To completely disconnect it from the mains voltage, the 
power plugs must be removed from the power socket.
Data transmission cables must not be connected or disconnected 
during a thunderstorm (lightning hazard).
Make sure that no objects (such as bracelets or paper clips) or liquids 
fall/spill into the device (risk of electric shock or short circuit).
Data cables must be adequately shielded to avoid interference.
The LAN wiring must comply with the standards EN 50173 and EN 
50174-1/2. The minimum requirement is a protected LAN line of 
category 5 for 10/100 MBps Ethernet, and/or of category 5e for 
Gigabit Ethernet. The requirements of the specification ISO/IEC 
11801 must be observed.
In an emergency (e.g. damage to housing, control elements or 
cables, the ingress of liquids or foreign bodies), switch the unit off 
immediately, pull the power plug out of the grounding outlet or the 
CEE outlet, and contact Service.
Proper operation of the device (in accordance with IEC 60950/DIN 
EN 60950) is only ensured if the casing is completely assembled and 
the dummy units for the installation openings have been put in place 
(electric shock, cooling, fire protection, interference suppression).
Install only system extensions that satisfy the requirements and rules 
governing safety and electromagnetic compatibility and relating to 
telecommunications terminal equipment. If you install other exten-
sions, you may damage the system or violate the safety regulations