Fujitsu BX600 S2 User Manual

Page of 173
38
 
 
PRIMERGY BX600 S2 Basic Unit
Installing the System in the Rack
Installing the Hardware
©
 c
o
g
n
it
as
Ge
s
e
lls
c
h
ft
 f
ü
r T
e
c
h
n
ik
-Do
k
u
m
e
nt
at
io
n
 m
b
2
007
 
P
fad:
 H:
\w
in
dows
\_p
roj
e
k
te\
B
x
z
\B
e
tr
ie
b
s
a
n
le
it
un
g\
V
e
rs
ion_
M
a
e
rz
-2
007
\A
rc
h
iv
\B
X
6
0
0
S
2
_
en\
bl
ad
e-u
s
.k
0
4
4.3.1
Mounting the Assembly Kit
Mounting the server in the PRIMECENTER/DataCenter Rack requires the 
following parts:
two support brackets 
two carrier rails (assembled)
12 plug washers (
) and screws
I
For general information see the technical manual for the relevant rack 
(see also 
).
To mount the PRIMERGY BX600 S2 basic unit in the rack, you must first mount 
two support brackets on the rear left support upright of the rack. The first one 
must be mounted level with the lower edge of the device, while the second must 
be mounted level with the upper edge of the first. The brackets are used for the 
rear fixing of the left carrier rail. 
Ê
See the installation instructions in the technical manual for the relevant rack 
model.
Ê
Mark the position of the lower edge of the basic unit on the support uprights.
Figure 6: Mounting the support brackets
Ê
Place the first support bracket at the appropriate height (level with the lower 
edge of the device) on the left rear support upright by inserting the 
positioning nubs (1 in 
) in the corresponding holes of the support 
upright.
Ê
Place the plug washers in the holes of the support uprights and secure the 
bracket with two screws.
1