Figure 76: Power supply unit: LEDs
There are three LED displays on the front of the unit to allow the status of the 
power supply unit to be monitored.
When the basic unit is operating normally, LEDs 1 and 3  will be on all the time 
and LED 2 will be off. If LED 2 signals a fault by lighting up, the power supply 
unit affected must be replaced as soon as possible. This can be done while the 
basic unit is still running (see 
1
On/off display (green LED)
Lights up when the PRIMERGY BX600 S3 basic unit is switched on.
2
Fault display (amber LED)
Lights up if a fault occurs on the power supply unit or if a fan
1
 fails.
1
If the large fan on the front fails, the power supply unit switches off. If one of the small fans on
the rear fails, the power supply unit continues to run. See 
 for the location of the power
supply unit fans.
3
Mains power supply display (green LED)
Lights up when the mains connection is re-established.
1 2 3
!