Power Supply Concept
Power Supply Units
V
CAUTION!
Because of chassis airflow disruption, the power supply unit slot should 
not be vacant and/or uncovered for more than five minutes when the 
system power is ON. Exceeding the five-minute limit may damage com-
ponents.
Each PSU dummy module includes three fans respectively.
There is one LED indicator (1 on 
) on the front of the PSU dummy 
module for monitoring the status of built-in fans.
Figure 80: PSU dummy module
If you want to install an additional power supply unit, you must first remove the 
PSU dummy module from the corresponding slot.
Ê
Remove the PSU dummy module from the corresponding slot.
Removal/installation is the same as for the power supply unit (see 
V
CAUTION!
Keep the dummy module for future use. If you remove a power supply 
unit and do not replace it with a new one, you must reinstall the 
dummy module.
Ê
Insert the additional power supply unit in the corresponding slot and connect 
it to the mains.