Fujitsu TX200 S6 User Manual

Page of 126
TX200 S6
Operating Manual
103
CSS components
Ê
Install the new HDD module, as described in 
V
CAUTION!
If you have removed a HDD module and do not install a new one in 
its place, put the dummy module back in its place for cooling, to 
comply with EMC regulations (regulations regarding electromagnetic 
compatibility), and for protection against fire. Ensure that the dummy 
module engages correctly in the bay.
8.2
Non-hot-plug components
If a defective non-hot-plug component is detected (for more information, see 
chapter 
 and the "ServerViewSuite Local 
Service Concept - LSC" manual on the ServerView Suite DVD 2), proceed as 
follows:
Ê
Exit all applications and shut down the server properly (see section 
).
Ê
Pull all power connectors out of the power outlets.
Ê
If the model is a rack model, remove the server from the rack (see section 
) and place the server on a 
table, for example.
Ê
Open the server (see section 
Ê
Press the Indicate CSS button on the system board (see the technical 
manual for the system board D2799).
The PRIMERGY Diagnostic LED of the defective CSS component lights up 
orange, thereby indicating which CSS component (memory module, fan or 
expansion card) on the system board must be replaced (see technical 
manual for the system board D2799).