Fujitsu TX200 S6 User Manual

Page of 126
TX200 S6
Operating Manual
57
Hardware installation
V
CAUTION!
Ensure that the safety lock has been inserted before the server is 
inserted (see 
).
V
CAUTION!
At least two people are needed to position the server in the rack.
(For the Japanese market, please refer to "
安全上の注意およびその他の
重要情報
".)
Ê
Extend the telescopic rails completely to the front (1). 
I
They must click into place so that they can no longer be moved.
Ê
Lower the server from above onto the projecting telescopic rails (2), (3). As 
you do this, the locking bar (4) engages.
Ê
Push the locking mechanism of both telescopic rails up (5).
Ê
For a final function test, slide the server in and out at least twice.The rails 
should move smoothly.
Ê
Push the server as far as it will go into the rack (6).
Ê
Fasten the server to the rack (7) using the two knurled screws (front panel).
Ê
Route the cables as described in the technical manual for the rack in 
question with the server pushed in.
4.3.3
Installation in 3rd party racks
I
The support systems from Fujitsu are suitable for use in any 3rd party 
racks for standard servers (installation depth 714 - 785 mm) without 
restrictions. 
Ê
Refer to the manual from the rack manufacturer for details of the mechanical 
installation and the climatic conditions.
V
CAUTION!
When installing in 3rd party racks, it must be ensured that an air flow 
from the front to the back of the rack is guaranteed.
Ê
Fit the required original parts (support bracket or cable management 
system).