CHAPTER 4 PCI Card Hot Maintenance in Red Hat Enterprise Linux 6 
4.7 Hot Addition of PCI Express cards 
106 
 
C122-E175-01EN 
 
7.  Check whether there is an error in added FC card by MMB Maintenance Wizard. 
This step is performed by the field engineer in charge of your system. 
For details on the operation of replacement, see step 8 to 11 of ‘Operation for Hot replacement of PCI 
Express card by Maintenance Wizard’ in 
”. 
8.  Check the version of the firmware 
It is required that the firmware version of new FC card is same as that of the FC card which had been 
replaced. If the firmware version of new FC card is coincident with that of the FC card which had been 
replaced (current firmware version), it is not necessary to update the firmware version of new FC card to 
current firmware version. 
If the firmware version of new FC card is not coincident with that of the FC card which had been replaced 
(current firmware version), update the firmware version of new FC card to current firmware version. 
For how to update the firmware version, see Firmware update manual for fibre channel card. 
Note 
If you cannot confirm the firmware version of the FC card before replacing due to the fault of the FC card, 
check the firmware version of the FC card which is same type as the faulty one to update firmware 
version. 
9.  Confirm the incorporation results 
The method of confirming is the same as that is performed in the replacement of FC card. See
 
Confirming the FC card incorporation results
 
4.7.4  Network card addition procedure 
 
NIC (network card) addition using hot plugging needs specific processing before and after PCI slot power-on 
or power-off. Its procedure also includes the common PCI Express card addition procedure. 
The procedure describes operations where a single NIC is configured as one interface. It also describes 
cases where multiple NICs are bonded together to configure one interface (bonding configuration). For 
bonding multiple NIC by using PRIMECLUSTER Global Link Services (GLS), see 'PRIMECLUSTER Global 
Link Service Configuration and Administration Guide Redundant Line Control Function' (J2UZ-7781). 
 
FIGURE 4.4 Single NIC interface and bonding configuration interface 
NIC addition procedure 
This section describes the procedure for hot plugging only a network card. 
Note 
When adding multiple NICs, be sure to add them one by one. If you do this with multiple cards at the same 
time, the correct settings may not be made. 
1.  Confirm the existing interface names. 
To confirm the interface names, execute the following command.  
Example: eth0 is the only interface on the NIC. 
# /sbin/ifconfig -a 
eth0  Link encap:Ethernet HWaddr 00:0E:0C:70:C3:38 
BROADCAST MULTICAST MTU:1500 Metric:1 
RX packets:0 errors:0 dropped:0 overruns:0 frame:0 
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 
collisions:0 txqueuelen:1000 
RXbytes:0 (0.0 b) TX bytes:0 (0.0 b)