Planning and designating a Main Distribution Frame
NN43021-310
Standard 02.01
December 2007
This chapter describes how to install and connect a CS 1000M system using
the BIX or Krone Test Jack Frame (UK) cross-connect terminals.
the BIX or Krone Test Jack Frame (UK) cross-connect terminals.
Note: The examples shown here are BIX and Krone cross-connect
systems. These items are commercially available, but are not supplied by
Nortel.
systems. These items are commercially available, but are not supplied by
Nortel.
This chapter contains the following procedures:
•
.
•
.
Terminal block requirements
The cross-connect terminal requires enough connecting blocks to terminate:
•
up to 16 25-pair cables for each IPE shelf
•
up to four 25-pair cables for each Media Gateway and Media Gateway
Expander
Expander
•
four conductors for the AUX cable from the Media Gateway
•
one 25-pair cable from each PFTU
•
wiring from telephones and trunks.
Installing the BIX cross-connect terminal
Procedure 11 describes how to install the BIX cross-connect terminal.
DANGER
Always use caution when installing or modifying
telephone lines. Do not install telephone wiring during a
lightning storm. Never touch uninsulated telephone
wiring, unless the line is disconnected at the network
interface.