DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
About This Book 
xvii
Upgrade Paths 
Upgrade Paths
The upgrade paths described in this book assume the system being upgraded is 
at the level of at least a G3V4. To upgrade prior systems to this starting point, 
refer to 
DEFINITY Communications System Generic 3r Upgrades and Additions.
 correlates each upgrade to an associated chapter number.
If upgrading from a pre-Release 5vs to a DEFINITY ECS Release 8si, refer to 
DEFINITY Enterprise Communications Server Release 8 Upgrades and Additions 
for R8si.
The following table indicates the processes and their corresponding time 
allotment. Not all processes are required for every upgrade; the table shows 
maximum times and includes high and critical reliability processes.
 
Table 1.
Software and Hardware Upgrade Chapters
Description
Chapter
1
 
2
3
4
5
Process
Minutes
Busyout multimedia interface circuit packs
2
Disable/enable TTI
2
Disable/enable scheduled maintenance
2
Disable/enable alarm origination to INADS
2
Save announcements (TN750/B Only)
40
Save translations
10
Backup disk
25-50
Verify software release
5
Replace disk drives and circuit packs
10
Set tone, lock, power down, power up, and unlock 
active and standby SPE
30
Restore disk full (both) 
30