Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-40
Standard Reliability 
5
Set Additional Administration
1. Type list configuration software-version and press 
Enter 
to compare the 
version number of the Release 8 software program (displayed on the 
terminal) with the TN786B version number (written on a label on the 
TN786B’s faceplate). If the version numbers are not the same, change the 
version number on the TN786B label so that they agree. 
2. Type change system-parameters customer-options and press 
Enter
Use this screen to enable the customer’s right-to-use options on the 
upgrade order. See 
DEFINITY Enterprise Communications Server Release 
8 Administrator’s Guide, for details.
3. Type change site-data and press 
Enter
. Use this screen to assign 
system-specific information (such as building, floor, stations, and so 
forth).
4. Type save translation and press 
Enter
. This instructs the system to write all 
translation information from memory to the translation card.
!
CAUTION:
If the terminal screen displays “translation corruption detected; call 
Lucent Technologies distributor immediately”, an error was detected 
in the translations. Call your Lucent Technologies representative.
Reconnect Cables to Upgraded EPN Cabinet
1. At the power distribution unit of the upgraded EPN, set the main circuit 
breaker to OFF.
NOTE:
Powering down an EPN without powering down the PPN will set off 
alarms. However, these alarms should clear after power is restored 
to each EPN.
2. Temporarily disconnect the lightwave transceivers and fiber optic cables 
from the appropriate carriers.
3. Replace the rear doors or rear panels previously removed.
4. At the EPN cabinet, reconnect the lightwave transceivers, fiber optic 
cables, and the connector cables.