Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-44
High Reliability 
5
High Reliability
Required Hardware
The equipment in 
 must be on-site before the upgrade begins. To 
place a claim for missing equipment, as part of the Streamlined Implementation 
process, call 1-800-772-5409, or the number provided by your Lucent 
Technologies representative.
Table 5-10.
Required Hardware
Equipment
Description
Quantity
J58890A
(PEC 6300-05X)
Processor Port Network
1
J58890AF
Expansion Control Carrier
1
106647985
TN775B Maintenance
1
103557294
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
2 or 6 
1
2 or 6 
1,2
1.
Use 2 for a high reliability system with 2 port networks; 6 with 3 port networks. Either 1
or 4 Expansion Interfaces (EIs) ship loose with the EPN equipment. The factory has
installed either 1 or 2 EIs in the new PPN.
2.
Required port network interfaces in a Release 8 system with the optional packet bus.
J58890TO-1 L1
Removable Media
4
407439975
20-Foot Multi-mode Fiber Optic Cable
1 or 3 
3
3.
Use 2 or 6 if the PPN and EPN(s) are remotely located. The fiber that previously
connected an upgraded G2 universal module (not a traditional module) to the G2 TMS
has the correct transceiver connectors and, therefore, can be reused.
106455348
or
106455363
9823-A Lightwave Transceiver
9823-B Lightwave Transceiver
2 or 6 
4
2 or 6 
5
4.
One pair for each fiber connection. For each connection, install one 9823-type
lightwave transceiver in an EPN and 1 in the PPN. A 9823-type transceiver can be
reused from each upgraded G2 universal module. Additional transceivers also ship
loose with the EPN equipment.