Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-75
Critical Reliability 
5
Critical Reliability
Upgrade Cabinets
An existing universal module cabinet is always upgraded to an EPN. 
Required Hardware
The equipment in 
 
must be on-site before the upgrade begins. To 
place a claim for missing equipment, as part of the Streamlined Implementation 
process, call “1-800-772-5409” or the number provided by your Lucent 
Technologies representative.
Table 5-14.
Required Hardware 
Equipment
Description
Quantity
PEC 6300-05X
Processor Port Network
1
J58890AF
Expansion Control Carrier
1
J58890BB-3
Port Carrier
1
106647985
TN775B Maintenance
1
103557294
or
103281788
TN776 Expansion Interface
TN570 Expansion Interface
4 or 12 
1
4 or 12 
1
,
2
1.
Use 4 for a critical reliability system with 2 port networks or 12 with 3 port networks.
Either 2 or 8 Expansion Interfaces (EIs) ship loose with the EPN equipment. The factory
has installed the other 2 or 4 EIs in the new PPN.
2.
Required port network interfaces in a Release 8 system with the optional packet bus.
J58890TO-1 L1
Removable Media
4
H-600-204 G1
ICC
3
3.
Required for an EPN in a critical reliability system.
407439975
20-Foot Multi-mode Fiber Optic Cable
2 or 6 
4
4.
Use 4 or 12 if the EPNs and the PPN are remotely located. Assuming acceptable
lengths, the fibers previously connecting an upgraded G2 universal module (not a
traditional module) to the G2 TMS have the correct transceiver connectors and can be
reused.
106455348
or
106455363
9823-A Lightwave Transceiver
9823-B Lightwave Transceiver
4 or 12 (See Note 1)
4 or 12 (See Note 1)
106689516
TN771D Maintenance Test
1 or 2