Adding or Removing Cabinet Hardware 
6-10
Add the Fiber Optic Cable 
6
Cabinet Preparation
1. Open the front door.
NOTE:
Administration may be required before removing the circuit pack in 
the following step.
2. Determine which slot (1 or 2) will contain the new fiber optic circuit pack. 
Remove the circuit pack or the blanking plate from this slot. 
NOTE:
If a circuit pack is removed from the required slot, it must be installed 
into a different slot in the cabinet. All translations associated with this 
circuit pack must also be moved.
3. Remove the circuit pack or the blanking plate from the slot next to the slot 
determined in step 2. Two consecutive open slots are required to install 
the fiber optic adapter.
NOTE:
If a circuit pack was removed in step 3, it will be replaced into the 
same slot, later in this section.
4. Install the new circuit pack.
5. Open the rear door.
6. From the rear, remove the I/O cable connector associated with the slot that 
will contain the new fiber optic circuit pack. See