Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-33
Install a New EPN Cabinet in an Existing System 
6
Figure 6-17.
Switch-Connected Release 8r with SNC in EPN
27. Connect an H600-278 Metallic Cable from Slot 2 in the Port Carrier in 
position B in Cabinet 4 (4B02) to Slot 19 on the Switch Node Carrier in 
position D in Cabinet 4 (4D19).
NOTE:
Both fibers from each PN must connect to the same slot number in 
each Switch Node Carrier. For example: if Slot 3A01 of EPN 3 
connects to Switch Node Carrier Slot 4E19, then Slot 3B02 of EPN 3 
must connect to Switch Node Carrier Slot 4D19.
28. Proceed to 
 to add the new fiber 
links.
Figure Notes:
1. Cabinet 1 (PPN)
2. Cabinet 4 (MCC EPN with One 
Duplex Switch Node)
3.
Cabinet 2, 3, and 5 through 16 (MCC or SCC 
EPNs) 
H600-278 Metallic Cable