Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-37
Remove an EPN Cabinet from an Existing System 
6
9. Type 
change system-parameters features
 and press 
Enter
. Use this 
screen to change the TTI field back to its previous setting before the 
upgrade.
10. When finished, place dust covers over all exposed fiber couplings that 
remain after the fiber optic cables are removed.
11. If any fiber optic cables were removed from Lightguide Interconnect Units 
(LIUs) or Fiber Patch Panels, remove the associated cable labeling. This 
will prevent confusion if existing fiber is later moved.
12. Return all unused equipment (not owned by the customer) to Lucent 
Technologies according to the requirements outlined in:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns
13. If any message waiting lamps are on, skip to 
Unadminister Fiber Links (Duplex Systems)
The fiber links routing to and from the EPN cabinet being removed must be 
unadministered before removing 
any hardware from the cabinet. 
!
CAUTION:
Failure to unadminister fiber links before removing hardware causes 
unnecessary alarm reports to INADS and causes errors that are very 
difficult to clear.
The fiber links are administered to match hardware and the Fiber Optic Cable 
Running List. Fiber link administration creates translation data by identifying the 
endpoint pairs for each link. To properly unadminister the fiber links, this 
translation data must be removed.
1. Type list fiber and press 
Enter
. All administered fiber connections are 
displayed. Make note of the fiber links to be removed. 
2. Type change fiber link and press 
Enter
. The Fiber Link Administration 
screen appears. On screen 1:
a. Remove the 
Board Location: 
information for ENDPOINT-1 and 
ENDPOINT-2. This is the cabinet, carrier, and slot that identifies the 
physical location of an SNI or EI circuit pack that is the first 
endpoint of the fiber link. Repeat for the remaining endpoints.
b. The 
Board Type
 field is display only.