Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-49
Add IP Interface Assembly 
6
Connect the Modem
NOTE:
These instructions are for connecting the U.S. Robotics modem supplied to 
U.S. customers only. If using a different modem, follow the manufacturer’s 
instructions on connecting the modem.
1. Connect the RS232 port of the modem to the MODEM connector of the 
TN802B external cable assembly. 
NOTE:
Check the labels near the connectors; the MODEM and COM2 
connectors look the same.
2. Connect an analog telephone line to the left most analog-line port on the 
modem as shown in 
3. Make sure that the modem’s DIP switches are set as shown in 
.
4. Plug the modem into an AC power outlet.
5. Turn on the modem using the switch on the front of the modem.
Figure 6-21.
External Modem Connections for U.S. Robotics Modem
Figure Notes
1. Connect analog line here.
2. DIP switch 5 must be up.
3. Connect MODEM connector here.
4. Connect power connector here.
1 2 3 4 5 6 7 8
modfrobo KLC 030499
2
3
4
1