DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-7
Upgrade the software and hardware 
1
Disable Scheduled Maintenance and Alarm 
Origination to INADS
1. To prevent scheduled daily maintenance from interfering with the update 
or upgrade, type change system-parameters maintenance and press 
Enter
.
2. If scheduled maintenance has begun, set the 
Stop Time
 field to 1 minute 
after the current time.
or
If scheduled maintenance has not begun, set the 
Start Time
 field to a 
time after the upgrade is completed. For example, if you start the upgrade 
at 8:00 p.m. and the upgrade takes 90 minutes, set the 
Start Time
 field 
to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets.
3. Type neither in the 
Alarm Origination to OSS Numbers 
field and 
press 
Enter.
NOTE:
For some software loads, set the 
Alarm Origination 
Activated
 field to and set the 
Cleared Alarm Notification 
and 
Restart Notification
 fields to disable or n before 
pressing 
Enter
Reconfigure the Tape (G3rV2, V3 R31.0 and 
Earlier)
NOTE:
Do not issue the list configuration software command before 
reconfiguring the removable media.
For some software loads, use 3-mem instead of large
If standard reliability:
1. Type configure tape large and press 
Enter
 to reconfigure the backup 
removable media for the 2 TN1650B Memory circuit packs. This command 
takes about 1 minute to complete.