Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-121
Add a Switch Node Carrier (High or Critical Reliability) 
6
Reseat DEFINITY LAN Gateway System
1. Reseat the LAN Gateway assembly into its backplane connectors.
Reseat DEFINITY AUDIX System
1. Reseat the AUDIX assembly to its backplane connectors.
Power Up System
1. At each EPN, if present, set the main circuit breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs the level 4 rebooting process, loading the system 
program and default or current translations from the disk. Rebooting takes 
5 to 11 minutes.
NOTE:
Ignore alarms for now.
4. Type reset system 4 and press 
Enter 
to copy the translations from 
removable media to memory.
5. Clear any alarms.
6. Type save translation [both] and press 
Enter 
if translation changes were 
made in Step 8 above.
7. Type restore disk [both] full and press 
Enter 
to copy the translations from 
removable media to disk.
8. After the system reboot is finished and all trouble cleared, verify that the 
EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores 
the system to the normal operating mode.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway. 
2. When the main menu appears, select 
Maintenance.
3. Select 
Reset System from the Maintenance menu.
4. Select 
Restart System from the Reset System menu.