Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory 
2-8
Upgrade the software and hardware 
2
Disable Scheduled Maintenance and Alarm 
Origination to INADS
NOTE:
Make sure scheduled daily maintenance does not interfere with the 
upgrade.
1. Type change system-parameters maintenance and press 
Enter.
2. If scheduled maintenance has begun, set the 
Stop Time
 field to 1 minute 
after the current time.
or
If scheduled maintenance has not begun, set the 
Start Time
 field to a 
time after the upgrade is completed. For example, if you start the upgrade 
at 8:00 p.m. and the upgrade takes 90 minutes, set the 
Start Time
 field 
to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets.
3. Type in the 
Alarm Origination 
field and press 
Enter
 if the field is not 
set to neither.
NOTE:
For some software loads
, set the 
Cleared Alarm Notification 
and 
Restart Notification
 fields to n before pressing 
Enter
.
Check Link Status
1. Type display communication-interface links and press 
Enter
. Write down 
all enabled links.
2. Type status link 
number and press 
Enter
. Repeat this step for all links.
3. Write down which links are in service.