Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory 
3-5
Read This First 
3
Software Upgrades
After a software upgrade, several features require special attention because of 
screen changes or potential naming conflicts in the upgrade process. Most of 
these changes and conflicts relate either to a software upgrade from standard 
ACD to Call Vectoring or to changes in the ARS/AAR features to compensate for 
increasing uncertainty in the North American numbering plan. Also, if ARS is 
enabled (when upgrading from IR1 Release 8 to GD-91 software), it may be 
necessary to modify the Call Type field on the ARS Analysis screen to “unk” for all 
call types except “iop” or “int.”
After the upgrade, the Software Associate should check these forms to ensure 
the upgraded translations are appropriate for the customer’s needs. Refer to 
DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide, 
for information to make any required changes.
ISDN Gateway
When upgrading to a Release 8r, upgrade the ISDN Gateway (if installed) to the 
correct software release. Call progress messages to the ISDN Gateway may be 
intermittently lost, therefore, this upgrade must occur at the same time as the 
system upgrade.
Contact your Lucent Technologies representative for the correct software release.
Single-Mode Fiber Attenuators
Attenuators may be required when using single-mode fiber. See the table below.
A different value attenuator may be required even though the fiber span is 
between the same 2 cabinets (local and remote cabinet). Refer to 
DEFINITY 
Enterprise Communications Server Release 8 Installation and Test for Multicarrier 
Cabinets for detailed fiber attenuator information.
106060718
5 dB attenuator
2 for each fiber connection
106060734
10 dB attenuator
2 for each fiber connection
106061021
15 dB attenuator 
2 for each fiber connection