Actions: 
• Select Channel 
o
  Choose channel parameters: 
ƒ
  Set the Fax parameters to meet your needs 
•  Set Max Baud Rate to match fax machine (2400 to 14400 bps) 
• Fax 
Volume 
should not be changed as it may impair function 
•  Jitter Value affects the time for packet reassembly 
•  Mode: Select T.38 or FRF 11 
ƒ
  Modem Relay Enable allows modem traffic through the VOIP system 
ƒ
  Adjusting Voice Gain and DTMF should not be done as it may adversely affect quality 
ƒ
  Select a Coder or allow Automatic negotiation 
ƒ
 Advanced 
Features 
• Silence 
Compression, 
when enabled, will not send silence packets 
•  Echo Cancellation removes echo to improve voice quality 
•  Forward Error Correction allows some bad packets to be recovered 
ƒ
  Choose Auto Call / OffHook Alert settings 
•  For automatically calling a remote VOIP without dialing (details in Chapter 4) 
ƒ
  Change Dynamic Jitter values if necessary (details in Chapter 4) 
ƒ
  Select any Automatic Disconnection options needed to ensure lines are not left “open” 
ƒ
  Configurable Payload Types are best left at their defaults. Not in the –SS models 
o
  The Copy Channel button is available for easily transferring these settings to the other channels 
•  Repeat for all channels to be used