Serial Port Profiles
TCP Port
The TCP port that the IOLAN will use to listen for incoming connections.
Default: 10000 plus the serial port number, so serial port 5 would have a 
default of 10005
Allow Multiple 
Hosts to Connect
When this option is enabled, multiple hosts can connect to the serial device that 
is connected to this serial port.
Default: Disabled
Enable IP Aliasing Enables/disables the ability to access a serial device connected to the serial port 
by an IP address (or host name that can be resolved to the Internet Address in a 
DNS network) instead of the IOLAN’s IP address and port number.
Default: Disabled
IP Address
Users can access serial devices connected to the IOLAN through the network 
by the specified Internet Address (or host name that can be resolved to the 
Internet Address in a DNS network).
Field Format: IPv4 or IPv6 Address
Connect To
When enabled, the IOLAN initiates communication to the Workstation/Server.
Default: Disabled
Host Name
The name (resolvable via DNS) or IP address of the configured host the 
IOLAN will connect to.
TCP Port
The TCP Port that the IOLAN will use to communicate to the client.
Default: 0
Connect to 
Multiple Hosts
When enabled, allows a serial device connected to this serial port to 
communicate to multiple hosts. 
Default: Disabled
Define Additional 
Hosts Button
Click this button to define the hosts that this serial port will connect to. This 
button is also used to define the Primary/Backup host functionality.
Initiate Connection 
Automatically
If the serial port hardware parameters have been setup to monitor DSR or 
DCD, the host session will be started once the signals are detected. If no 
hardware signals are being monitored, the IOLAN will initiate the session 
immediately after being powered up.
Default: Enabled
Initiate Connection 
When any data is 
received
Initiates a connection to the specified host when any data is received on the 
serial port.
Default: Disabled
Initiate Connection 
When 
<hexadecimal 
value
> is received
Initiates a connection to the specified host only when the specified character is 
received on the serial port.
Default: Disabled
Send name on 
Connect
When enabled, the port name will be sent to the host upon session initiation
This 
will be done before any other data is sent or received to/from the host
Default: Disabled
Permit 
Connections in 
Both Directions
When this option is enabled, the connection can be initiated by either the 
IOLAN or a host.
Default: Disabled