mode export. Asynchronous exports acknowledge writes that are not actually on disk, and so administrators
should consider the risks of failure carefully in these situations.
The XenServer NFS implementation uses TCP by default. If your situation allows, you can configure the
implementation to use UDP in situations where there may be a performance benefit. To do this, specify the
device-config
 parameter 
useUDP=true
 at SR creation time.
Warning:
Since VDIs on NFS SRs are created as sparse, administrators must ensure that there is enough disk space on
the NFS SRs for all required VDIs. XenServer hosts do not enforce that the space required for VDIs on NFS
SRs is actually present.
Creating a shared NFS SR (nfs)
Device-config parameters for nfs SRs:
Parameter Name
Description
Required?
server
IP address or hostname of the
NFS server
Yes
serverpath
path, including the NFS mount
point, to the NFS server that
hosts the SR
Yes
To create a shared NFS SR on 
192.168.1.10:/export1
 use the following command.
xe sr-create host-uuid=
<host_uuid>
 content-type=user \
name-label=
<"Example shared NFS SR">
 shared=true \
device-config:server=
<192.168.1.10>
 device-config:serverpath=
</export1>
 type=nfs
LVM over hardware HBA
The LVM over hardware HBA type represents disks as VHDs on Logical Volumes within a Volume Group
created on an HBA LUN providing, for example, hardware-based iSCSI or FC support.
XenServer hosts support Fibre Channel (FC) storage area networks (SANs) through Emulex or QLogic host
bus adapters (HBAs). All FC configuration required to expose a FC LUN to the host must be completed
manually, including storage devices, network devices, and the HBA within the XenServer host. Once all FC
configuration is complete the HBA will expose a SCSI device backed by the FC LUN to the host. The SCSI
device can then be used to access the FC LUN as if it were a locally attached SCSI device.
Use the 
sr-probe command to list the LUN-backed SCSI devices present on the host. This command forces
a scan for new LUN-backed SCSI devices. The path value returned by 
sr-probe for a LUN-backed SCSI
device is consistent across all hosts with access to the LUN, and therefore must be used when creating
shared SRs accessible by all hosts in a resource pool.
The same features apply to QLogic iSCSI HBAs.
See 
 for details on creating shared HBA-based FC and
iSCSI SRs.
Note: