Honeyware VX6 User Manual

Page of 48
Connecting an AC/DC Power Supply
Note:
The Honeywell-approved AC Power Supply and Adapter Cable are only intended for use in a 25ºC (77ºF) maximum
ambient temperature environment.
1. AC Input Cable (US only)
2. DC Output Cable
In North America, this unit is intended for use with a UL Listed ITE power supply with output rated 12 – 80VDC, minimum 75W.
Outside North America, this unit is intended for use with an IEC certified ITE power supply with output rated 12 – 80VDC,
minimum 75W.
The external power supply may be connected to either a 120V, 60Hz supply or, outside North America, to a 230V, 50Hz
supply, using the appropriate detachable cordset. In all cases, connect to a properly grounded source of supply provided with
maximum 15 Amp overcurrent protection (10 Amp for 230V circuits).
1. Turn the VX6 off.
2. Connect the detachable cordset provided by Honeywell (US only, all others must provide their own cable) to the
external power supply (IEC 320 connector).
3. Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains).
4. Connect the watertight connector end to the VX6’s Power Connector by aligning the connector pins to the power
connector; pushing down on the watertight connector and twisting it to fasten securely.
5. Turn the VX6 on.
3-3