Intel SE7501CW2 User Manual

Page of 25
Intel Server Board SE7501CW2
 
Installation and Integration Guide 
Installing the Processor Wind Tunnel
 
The following instructions apply to the base Intel Server Chassis SC5200 and reference 
chassis installations. Direct the airflow from the processor wind tunnel toward the rear of 
the chassis as shown.  
 
Attaching the Heat Sink Fan 
Install the processor wind tunnel center section over the 
heat sink. The plastic tabs on the wind tunnel center 
section must engage the tabs on the retention 
mechanism. Make sure the fan’s sticker is facing away 
from the assembly, so that the airflow is into the 
assembly. 
 
 
 
 
 
Attaching the Fan/Intake Assembly 
1.  Position the fan/intake assembly at approximately 45°, 
and engage the clip at the top of the tunnel as shown.  
2.  Gently squeeze the two tabs on the assembly, and 
insert them into the two mating slots on the wind 
tunnel.  
3.  Rotate the fan/intake downward to engage the mating 
clips on the wind tunnel. 
14