Wagner SprayTech Finish 250 User Manual

Page of 30
9
Finish 370 / 250
GB
DESCRIPTION OF UNIT
3.6 
TECHNICAL DATA FINISH 250
Voltage :
230 V AC, 50 Hz
Fuses :
16 A time-lag
Unit connecting line :
6 m long, 3 x 1.5 mm2
Max. current consumption
hose heating :
4,6 A
Degree of protection :
IP 54
Acceptance capacity :
1,1 kW
Max. operating pressure :
25 MPa (250 bar)
Max. volume fl ow :
2.2 l/min
Volume fl ow at 12 MPa
(120 bar) with water :
1.8 l/min
Max. temperature of the 
coating material :
43 °C
Max. viscosity :
15,000 mPas
Empty weight pump :
28 kg
Hydraulic oil fi lling 
quantity :
0.65 liter
Max. vibration at the spraygun: lower than 2.5 m/s2
Max. sound pressure level:
74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60 
m above fl oor, 12 Mpa (120 bar) operating pressure, 
reverberant fl oor
Voltage :
230 V AC, 50 Hz
Fuses :
16 A time-lag
Unit connecting line :
6 m long, 3 x 1.5 mm2
Max. current consumption
hose heating :
6.0 A
Degree of protection :
IP 54
Acceptance capacity :
1.3 kW
Max. operating pressure :
25 MPa (250 bar)
Max. volume fl ow :
2.9 l/min
Volume fl ow at 12 MPa
(120 bar) with water :
2.3 l/min
Max. temperature of the 
coating material :
43 °C
Max. viscosity :
15,000 mPas
Empty weight pump :
29.5 kg
Hydraulic oil fi lling 
quantity :
0.65 liter
Max. vibration at the spraygun: lower than 2.5 m/s2
Max. sound pressure level:
74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60 
m above fl oor, 12 Mpa (120 bar) operating pressure, 
reverberant fl oor
3.7 
TECHNICAL DATA FINISH 370
Before start with the backfi tting, pull of main 
plug of socket, disassemble suction system 
and high pressure hose
  1