Vulcan-Hart VSX5GC User Manual

Page of 16
– 16 –
FORM 31051 Rev. B (Jan. 2003)
PRINTED IN U.S.A.
TROUBLESHOOTING
WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE STEAMER.
Symptom
Possible Cause
Burner does not come on.
Gas supply is off, power cord is unplugged or switch is off.
Burner control goes into 100% lockout. If symptom persists,
contact Service.
Boiler dirty (carbon black).
Contact  Service.
Water flows into compartment.
Delime. If symptom persists, contact Service.
Door leaks.
Check door gasket for damage. If adjustment is needed,
contact Service.
Water accumulates in compartment.
Drain clogged.
Water not being supplied to boiler.
Water supply valve is off. Check water supply pressure.
If symptom persists, contact Service.
Water flows into drain when unit is off.
Contact  Service.