Symptom
Possible Cause
Burner does not come on.
Gas supply is off, power cord is unplugged or switch is off.
Burner control goes into 100% lockout. If symptom persists,
contact Service.
Burner control goes into 100% lockout. If symptom persists,
contact Service.
Boiler dirty (carbon black).
Contact Service.
Water flows into compartment.
Delime. If symptom persists, contact Service.
Door leaks.
Check door gasket for damage. If adjustment is needed,
contact Service.
contact Service.
Water accumulates in compartment.
Drain clogged.
Water not being supplied to boiler.
Water supply valve is off. Check water supply pressure.
If symptom persists, contact Service.
If symptom persists, contact Service.
Water flows into drain when unit is off.
Contact Service.