GE GSD6300 User Manual

Page of 44
– 19 –
through the hub to the lower spray arm and to the
main conduit.  The main conduit supplies water to
the middle and upper spray arms.
Inlet Cover
Caution: Use care to avoid breaking the clip on
the hub when removing the main conduit from hub.
Remove the lower wash arm and main conduit to
gain access to the inlet cover and sump.
Fine Filter, Sump Filter, and Sump
The dishwasher must be removed from its instal-
lation to gain access to the sump.  The sump
must be removed to allow removal of the fine filter
and sump filter.
Circulation Pump
Note: It is extremely important that the self-tapping
ground-wire screw on the circulation pump is
tightened securely.
The dishwasher must be removed from its instal-
lation to gain access to the circulation pump.  The
circulation pump can be activated using service
mode (refer to the 
Service Mode
 chapter).  Refer to
schematic or strip circuit for motor resistance
value.
Lower Wash Arm
Lift and rotate (ccw) the lower spray arm to re-
move it from the hub.  Clean the screen on the
water return if necessary.
Middle Wash Arm
Refer to illustration for disassembly.
Upper Wash Arm
Remove screw, plastic bearing, and upper wash
arm.
Conduit Carrier
Hub
Middle
Spray
Arm
Mid
Bracket
Nut
Bearing
Upper Rack
Tab
Mid Conduit
Screw
(Optional)
y arm for bits of
her foreign
or rotation.
-Level
CIRCULATION PUMP
J2-1
M
WR
NX
10
NO
COM
WX
DOOR
INTERLOCK
N
L1 Output from J2-1