Jackson FL-10 Leaflet

Page of 2
Performance/Capacities
P
ot
washer
s
• Water usage — 6.5 gallons per cycle
• 12 cycles per hour
• Fully automatic cycle - 260 seconds
• Incoming water pressure regulator
• Internally mounted electric booster
heater
- Capable of minimum 60°F temper-
ature rise for required 180°F
minimum sanitizing rinse temperature
• One (1) 9 KW  Heating Element in a
9 1/2 gallon rinse tank
• Two (2) Rotating Wash Arms - 
1 upper & 1 lower
• Stationary Rinse Nozzles - 
Top & Bottom
• 30 Gallon Wash Tank
• Electromechanical controls
- Safety door switch
- Temperature control thermostat 
and low water protection
• Construction - 12 & 14 gauge 
stainless steel
• Operational and cleanability features
- High pressure, all stainless steel
wash arms 
- 28 3/4” wide x 30 1/2” high door
opening 
- Double filtration system
- Externally mounted spray down
hose with spray gun nozzle
- Waterproof LED ditigal gauges
- Three wash cycles
• Installation features
- Stainless steel control panel - easily
accessible      
- Adjustable bullet feet
- Detergent/rinse additive signal 
connection fuse box
Standard Features
Operating Capacity
Racks per Hour
12
Operating Cycle (Seconds)
Light
Wash Time 
180
Dwell Time 
20
Rinse Time
60
Total Cycle 
260
Medium
Wash Time 
300
Dwell Time 20
Rinse Time
60
Total Cycle 
380
Heavy
Wash Time 
420
Dwell Time
20
Rinse Time
60
Total Cycle 
500
Operating Temperatures
Wash — °F (Minimum)
150
Rinse — °F (Minimum)
180
Frame Dimensions (Inches)
Width
32
Depth
44 (46 gas)
Height
84 1/2
Height (door open)
Electric
103 1/2
Gas
106
Wall Clearanse (Minimum)
16
Wall Clearance 
(Control Panel Side)
36 Wall
Clearance (Back)
12
Shipping Weight (Lbs.)
950
Shipping Size (Inches)
Width
42
Depth
60
Height
90
Electrical Rating
Wash Pump Motor Horsepower
7.5
Full Load Amps
208V
230V
460V
Electric
71.0
65.2
33.6
Steam Injectors
46.0
42.6
22.3
Steam Coils
22.0
20.0
11.0
Gas
46.0
42.6
22.3
Gas Requirements
Gas Connection (NPT)
1/2
Natural Gas (Inches-water column)
Minimum inlet
6.0
Main Manifold
3 1/2
BTU
36,000
Propane (Inches-water column)
Minimum inlet
11.0
Main Manifold
6.0
BTU
36,000
3” Stainless steel chimney on back of machine
Steam Requirements
Steam connection (NPT)
3/4
Injectors (Lbs per hour)
15
Coils (Lbs per hour)
33
Water Requirements
Inlet Temperature (Minimum)
140°F
Gallons per Hour
78
Gallons per Rack
6.5
Waterline Size IPS (Minimum) (Inches)
1/2
Drainline Size IPS (Minimum) (Inches)
1 1/2
Flow Pressure (PSI)
15-25
Power/Connections