Jackson JP-24 User Manual

Page of 59
JP-24 Technical Manual 7610-002-49-79 Rev. D
Issued: 03-06-2006  Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS of the JP-24B/JP-24BF
3
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (RACKS/HOUR)
RACKS PER HOUR                               
30
DISHES PER HOUR                               
600
GLASSES PER HOUR                            
600
OPERATING CYCLE (SECONDS)
WASH TIME
82
DRAIN TIME
28
RINSE TIME
10
TOTAL CYCLE TIME (MINUTES)
2
5 MINUTE TIMER OPERATING CYCLE (SECONDS)
WASH TIME
262
DRAIN TIME
28
RINSE TIME
10
TOTAL CYCLE TIME (MINUTES)
5
TANK CAPACITY (LITERS) (GALLONS)
WASH TANK                                                (21.5) 5.65
RINSE TANK                                                (11.4) 3
TEMPERATURES
WASH --- (MINIMUM)                               (65.6°C)  150°F
RINSE --- (MINIMUM)                               (82.2°C)  180°F
WATER REQUIREMENTS
INLET TEMPERATURE 
(40° Booster Heater) 
(82.2°C) 140°F 
INLET TEMPERATURE 
(70° Booster Heater)
(43.3°C) 110°F 
GALLONS PER HOUR
(198.7L) 52.3
WATER LINE SIZE I.P.S. (Minimum)            (1.27 cm) 1/2”
DRAIN LINE SIZE I.P.S. (Minimum)          (3.81 cm) 1 1/2”
FLOW PRESSURE P.S.I.
20
A5
FLOW, GALLONS PER MINUTE
(27L) 7.1
ELECTRICAL REQUIREMENTS
WASH MOTOR HP
3/4
NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip cir-
cuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is dis-
played here. Always verify with your electrical service con-
tractor that your circuit protection is adequate and meets all
applicable national and local codes. These numbers are pro-
vided in this manual simply for reference and may change
without notice at any given time.
RINSE
TYPICAL
HEATER   
TOTAL     ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
208      1      50
6.7KW
40
50 AMP
230      1      50
8.2KW
43
60 AMP
208      1      50
8.2KW
47
60 AMP
230      1      50
10KW
51
70 AMP
220      1      50
9.15KW 
48
60 AMP
208      1      60
6.7KW
39
50 AMP
230      1      60
8.2KW
46
60 AMP
208      1      60
8.2KW
42
60 AMP
230      1      60
10KW
50
70 AMP
460      1      60
480/8.2KW
11
15 AMP
460      1      60
480/9.6KW
14
20 AMP
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.