Managing Appliances
124
EncrypTight User Guide
The amount of time it takes to complete a software upgrade depends on the appliance model and speed of 
the link. The upgrade time increases proportionately to the decrease in the link speed. If software is not 
successfully loaded to any particular appliance in a predefined time frame, the connection times out. The 
software upgrade timeout is user-configurable (Edit > Preferences > ETEMS > Communications). 
Prior to upgrading an appliance, we recommend making a backup copy of the existing file system. If you 
experience a problem with an upgrade, you can then restore the appliance’s file system from the backup 
copy. A backup is created automatically on ETEP appliances. 
Figure 40
Upgrade remote appliances first when managing appliances in-line, where 
management traffic flows through the data path 
If you are managing your EncrypTight appliances in-line as shown in 
, we recommend 
performing a software upgrade in two stages. First, upgrade all the appliances at remote sites and reboot 
them. When the remote site appliances are up and operational, upgrade the local site appliance, which is 
co-located with the ETEMS management station. Upgrading the local appliance at the same time as the 
remote appliances can cause connectivity with the management station to be lost and the remote site 
upgrades to fail.