Smeg CC62MFX5 User Manual

Page of 24
 
Instructions for the installer
 
 
20 
 
14.
  INSTALLATION 
 
14.1
  Technical information 
 
Appliance type 
See rating plate 
 Electrical 
connections 
220 - 240V~ 50Hz / 220 - 240V 2
∼ / 380 - 415V 2N∼ 
 
Required protection fuse for the oven 
30 Amps 
 Hob 
rating 
Gas 
 Oven 
rating 
Electric 
 
Maximum electrical power 
5.38 kW 
 
Small oven grilling rating 
Electric 
 
Small grill power 
1.85 kW  (230 V) 
 
Large grill power 
2.65 kW  (230 V) 
 
Ovens lightings 
25 W 
(230 V) 
 
OVEN CAVITY DIMENSIONS 
Large oven 
Small oven 
 Height 
(cm) 
34 
17 
 Width 
(cm) 
41 
41 
 Depth 
(cm) 
40 
41 
 Internal 
volume 
(cm
2
) 55760 
28577 
 
14.2
  The rating plate 
 
CHECK THAT THE VOLTAGE AND DIMENSIONING 
OF THE SUPPLY LINE CORRESPOND TO THE 
CHARACTERISTICS SHOWN ON THE PLATE 
FIXED TO THE REAR PROTECTIVE COVER OF 
THE APPLIANCE. 
THIS PLATE MUST NEVER BE REMOVED. 
 
14.3
  Electrical connection 
 
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE 
METHODS REQUIRED BY SAFETY RULES. 
 
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE 
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH 
APPLICABLE REGULATIONS. 
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN. 
NEVER UNPLUG BY PULLING ON THE CABLE. 
 
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN, 
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT 
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. 
NEVER ATTEMPT TO REPAIR THE APPLIANCE. 
 
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND 
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD 
CAUSE OVERHEATING AND RISK OF BURNS. 
 
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT 
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN 
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.