*Note: A 8" minimum spacing to adjacent side wall is required
Wall Installation: Wall installations require 25”  
countertop depth. When cabinet is flush against  
the wall, the fan housing can be rotated to the  
horizontal position for direct venting through  
rear wall. Make a countertop cutout in the  
range cabinet according to unit dimensions  
and installation type. Duct hole is positioned in  
back of cabinet for through-the-wall ducting. 
Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/
islands a minimum 26” countertop depth is suggested. 
Blower should be in vertical position. Island or  
peninsula cabinets may require adjustment in cutout 
depth and/or location within the width dimensions. 
Duct hole is positioned in bottom of cabinet for island 
or peninsula installation.
Slab Installation: For peninsula or island installation 
and rear wall ducting, 
6” PVC duct or locally 
approved piping should be used if installing under 
a poured concrete slab.
Installation Information:
 Before installing, consult  
installation instructions, packed with product, for  
current dimensional data.
Note: These cooktops are approved for indoor use only.
30
3-1/4 x 10
4-3/16
28-3/4
21-3/4
20-1/2
22
 
Tie down bolt
on each end
Select appropriate
duct cutout
(see ducting installation instructions.)
Pressure regulator
Wiring box cover
Grease
container
9-1/2
29 +
_1/16 
1-7/8"
Min.
15/16"
Min.  
clearance
Blower can be swiveled 90
°
14-3/16
 9
30
21-3/4
21 +
_1/16
JGP990SEL 
GE Profile
™ 
30" Downdraft Gas Cooktop
 
Dimensions and Installation Information (in inches)