Flue  assembly  -  Mounting  the  hood  body   
•  Insert  the  upper  duct  and  fix  it  on  the  top  of  the  upper  duct 
connection using the 12c screws (2.9 x 9.5) supplied with the 
appliance. 
Recirculation version 
•  It is necessary to make sure that the air outlet connection 15 is 
placed correctly so that the air outlet grid in it corresponds to 
that of the chimney.  
•  If  the  grids  of  the  two  parts  are  not  corresponding  to  each 
other, it will be necessary to remove the chimney and to adjust 
the  position  of  the  air  outlet  connection  15,  and  at  last  to  as-
sembly the parts again by following the earlier indications. 
Before fixing the hood body to the frame: 
•  Open the suction panel by turning the specific knob. 
•  Disconnect the panel from the hood canopy by sliding the fix-
ing pin lever.
•  Remove the grease filters from the hood body. 
•  Remove any activated charcoal filters. 
•  From below, use the 4 screws 12f (M6 x 10) provided to fix the 
hood body to the frame.
12c
12f
ELECTRICAL  CONNECTION 
•  Connect the Hood to the mains power supply, inserting a two-
pole  cut-out  switch  with  contact  aperture  of  at  least  3  mm 
along the line. 
•  Pull the Comfort Panel to open it, ensure that the supply cable 
connector is properly inserted into the Suction device socket 
•  Join the connectors.  
•  Install the odour filter and the charcoal filter in case the hood is 
to be used in recycling version. 
•  Install  the  grease  filter  again,  and  successively  the  suction 
panel.