Franke Consumer Products FPL 607 I User Manual

Page of 88
EN
1
4
14
Ducted  version  air  exhaust  system  Connection 
When  installing  the  ducted  version,  connect  the  hood  to  the 
chimney  using  either  a  flexible  or  rigid  pipe  ø  150 or 120  mm, 
the choice of which is left to the installer. 
•  To  install  a  ø  120  mm  air  exhaust  connection,  insert  the  re-
ducer flange 9 on the hood body outlet. 
•  Fix the pipe using the pipe clamps 25 provided.  
•  Remove any activated charcoal filters. 
 
9
ø 150
ø 120
25
25
RECIRCULATION  VERSION  AIR  OUTLET 
•  Insert the reducer flange 9 on the air outlet of the extractor. 
•  Attach  the  adhesive  Novastik  gasket  13  to  the  air  outlet  con-
nection 15 and fix this to the upper frame using the 2 knobs 24.
•  Fix the air outlet connection extension piece 14 to the air outlet 
connection 15.
•  Connect  the hood  air outlet  to  the  flange  in  the  lower  part  of 
the junction using a rigid or flexible ø 120 tube (by installer’s 
choice). 
14
15
24
15
14
15
9