Franke Consumer Products FPL 907 I User Manual

Page of 88
EN
1
9
19
Charcoal  filter  (recycling  version) 
•  This filter cannot be washed or regenerated. It must be replaced when the EF appears on the 
display or at least once every 4 months.  
Activation of the alarm signal  
•  In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later. 
•  Switch off the hood and the lights. 
•  Disconnect the hood from the mains supply. 
•  When restoring the connection press and hold B-key. 
•  When releasing the key two rotating rectangles appear on the display. 
• Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: 
  •  2 flashes with EF - charcoal filter saturation alarm ACTIVATED 
  •  1 flash with EF - charcoal filter saturation alarm DEACTIVATED.  
REPLACING  THE  CHARCOAL  FILTER 
Reset of the alarm signal 
•  Switch  off  the  hood  and  the  lighting.  If  the  24h-function  has 
been activated this has to be deactivated. 
•  Press the E-key until the display is unlit. 
Replacing of the filter  
•  Open the comfort panels pulling them downwards. 
•  Remove the metal grease filters. 
•  Remove  the  saturated  charcoal  filter  by  releasing  the  fixing 
hooks 
•  Fit the new filter and fasten it in its correct position. 
•  Put the metal grease filters in their seats. 
•  Close the comfort panels.  
Lighting
LIGHT  REPLACEMENT 
20 W halogen light. 
•  Remove the snap-on lamp cover by levering it from under the 
metal ring, supporting it with one hand. 
•  Remove  the  halogen  lamp  from  the  lamp  holder  by  pulling 
gently. 
•  Replace  the  lamp  with  a  new  one  of  the  same  type,  making 
sure that you insert the two pins properly into the housings on 
the lamp holder. 
•  Replace the snap-on lamp cover.