Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “LP” or “NAT” position. Turn over the spring 
retainer so the “NAT” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure to 
the regulator should be as follows for operation and checking 
the regulator setting:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure 
shown on the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5 kPa).
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner base.
4. Apply masking tape to the end of a 
7 mm nut driver to help 
hold the gas orifice spud in the nut driver while changing it. 
Insert nut driver into gas opening and press down onto the 
gas orifice spud and remove by turning the gas orifice spud 
counterclockwise and lifting out. Set gas orifice spud aside.
5. Replace with correct Natural gas orifice spud. See the 
“Natural Gas Orifice Spud/Hood Chart.”
Use the following chart to find the exact orifice spud 
placement.
Remove choke from medium burner base.
Natural Gas Orifice Spud/Hood Chart
6. Place LP gas orifice spuds in plastic parts bag for future use 
and keep with package containing literature.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
A. Access cap
B. Gasket
C. Gas pressure regulator
D. NAT position
E. LP position
A
B
C
A
B
C
D
E
Large Dual Burner
A. Burner cap
B. Burner base
Medium Burner
A. Burner cap
B. Burner base
C. Choke (for use with medium 
burner, LP gas only)
Small Burner
A. Burner cap
B. Burner base
Burner orifice spud
A. Size stamp or color
Burner Rating
Size
Burner Style
5,000 BTU
1.01 mm
Small burners
15,000 BTU
1.75 mm
Medium burners
20,000 BTU
2.10 mm