Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that 
will not operate if plugged into an outlet that is not properly 
polarized.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
 National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 
The wiring diagrams are provided with this cooktop. The 
wiring diagrams are located inside the control console and in 
the “Wiring Diagrams” section.
Gas Supply Requirements
Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the cooktop must be conducted 
according to the manufacturer’s instructions.
Type of Gas 
Natural Gas:
This cooktop is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 
This cooktop is factory-set for use with Natural gas. To 
convert to LP gas, see the Gas Conversion instructions 
provided in the package containing literature. The model/
serial rating plate located on the left underside of the cooktop 
burner base has information on the types of gas that can be 
used. If the types of gas listed do not include the type of gas 
available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. To convert to LP 
gas, use the LP gas conversion kit provided with the cooktop and 
see the “Gas Conversions” section.
Gas Supply Line 
Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the 
cooktop location. A smaller size pipe on longer runs may 
result in insufficient gas supply. With LP gas, piping or tubing 
size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers 
determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®†
 tape. 
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.