SERVICE (cont.)
SOLENOID VALVE (INLET) (all Models)
FIG. 48 INLET SOLENOID VALVE
Location:
  The inlet solenoid is located inside on the rear of 
the dispenser base.
Test Procedures:
1.  Disconnect the dispenser  from the power 
source.
2.  Disconnect the two wires from the solenoid 
valve. 
3.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described, reconnect the two 
wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
4.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source.  Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound  as the coil magnet attracts.
5.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If the sound is not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove the two wires from the solenoid valve.
2.  Turn off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Remove the two #8-32 screws securing the sole-
noid to the dispenser base. Remove solenoid.
5.  Install new solenoid valve on the dispenser base 
and secure with the two #8-32 screws.
6.  Securely fasten the water lines to and from the 
solenoid valve.
7.  Refer to Schematic Wiring Diagrams when recon-
necting the wires.
P1217
FIG. 49 INLET SOLENOID VALVE TERMINALS
Late Models
Early Models
120V  1.2 kΩ
230V  3.84 kΩ
120V  622 Ω
230V  1555 Ω
P4102.40
FMD DBC-3 shown
42672 122209