Area Requirements
Verify the following:
•  Floors can support refrigerator’s weight plus 
approximately 1200 pounds (544 kg) of food 
weight.
•  Finished kitchen floor height has to be level. 
Appliance must be shimmed to the floor level if 
the floor heights are not equal to make sure air 
vents are not obstructed.
•  Remove anything attached to rear or side walls 
that can obstruct refrigerator opening.
•  Cutout dimensions are accurate.
•  Electrical outlet is in correct location.
Do not install this unit next to any other refrigerator 
or freezer except another Liebherr model. Liebherr 
models are designed to allow side-by-side 
installation. They are equipped with a heating 
element to eliminate condensation when units are 
installed side by side. Installing this unit next to any 
other refrigerator or freezer can cause condensation 
or cause damage to the Liebherr unit.
Electrical Requirement
If codes require a separate grounding circuit to be 
used, have a qualified electrician install the circuit.
!
WARNING
Do not ground to a gas pipe. Check with a 
qualified electrician if you are not sure the 
appliance is properly grounded. Do not 
have a fuse in the neutral or grounding 
circuit.
!
WARNING
ELECTRICAL SHOCK HAZARD
•  Electrically ground refrigerator.
•  Do not use an extension cord.
•  Failure to follow these instructions 
   could result in fire or electrical shock.
!
WARNING
ELECTROCUTION HAZARD
Electrical Grounding Required. This 
appliance is equipped with a three-prong 
(grounding) polarized plug for your 
protection against possible shock hazards.
  DO NOT remove the round grounding 
   prong from the plug.
  DO NOT use a two-prong grounding 
   adapter.
   DO NOT use an extension cord to 
connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-by-
side installation) fused electrical supply is required. 
We recommend using a dedicated circuit for this 
appliance to prevent electrical overload. Follow 
the National Electrical Code and local codes and 
ordinances when installing the receptacle.
Blocking For Safety
The anti-tip brackets must be installed to prevent 
the unit from tipping after it is installed. Refer to 
Blocking For Safety.
Unit Venting
DO NOT restrict the air flow. Air flow must be 
provided for the unit to operate. The factory air 
vents provide 31 square inches (200 cm²) of air 
flow per unit. If you are replacing the factory air 
vents with an overlay, the air flow must be the 
same or greater than the factory air vents.