HDC II Programming Guide
Introduction
July, 2003
6
6730018
The operator is protected by the anti-jackpot program of the system.   It is con-
ceivable that a customer could prevent cups from reaching the sensing area of the 
cup station in order to steal the cups and then get his or her money back for the 
vend.  Under the SureVend™ Anti-Jackpot system, the operator can lose no more 
than two cups in a row per ring. Then that ring is temporarily placed out-of-ser-
vice both to protect the customer and to discourage theft.  The amount of time 
that the cup ring is out-of-service is programmable from 0 to 99 minutes.  After 
the time has elapsed, the cup ring will return to service but the count of the two 
failures is kept.  If the previous problem was theft, then the next vend attempt 
from that ring will be successful and the count of the two previous failures will 
be erased.  If the problem is an actual system failure, then the third failure will 
permanently place that cup ring out of service until a service technician visits the 
machine.
Alternate cup vends and mug vends still work as before.  If a cup ring is out of 
service due to SureVend™ the alternate vend will only be from a selected large 
cup to a small cup at the small cup price.  An induced SureVend™ failure cannot 
cause an alternate vend from a selected small cup to a large cup at the small cup 
price.  This protects the operator from customers trying to get large cup drinks at 
a small cup price.  (SureVend™ will not automatically switch to a different cup 
size in mid-vend because it cannot be ensured that correct change will be 
returned for the new price.) 
SureVend™ can be turned off if desired (see "Turn SureVend™ On or Off", 
PAGE 42
).
THE SUPERVISOR MODE
The supervisor is allowed to do things that a normal user cannot, like controlling 
access to certain modes.  The supervisor can lock out any of the programming 
modes to anyone who does not have the right "key".  Once a supervisor enters the 
proper code, he or she will be able to:
Change the supervisor access code
Lock out any or all of the service keypad modes
Set whether data is cleared with 
 or after being downloaded into a 
portable data collection device
Grant or deny access to data items during DATA RECALL
Modify the machine configuration