page 40
5 Troubleshooting 
CONDITION: No sound, even though 
the amp has power. 
Power LED is on 
with out fl ashing and the amp is receiving an input 
sig nal. Signal indicator is on or fl ashing.
POSSIBLE REASON
•  Speakers not connected.
•  Open circuit due to speaker failure.
•  Ready LED is off. Channel has been set to 
standby mode via the software.
•  Amplifi er is in blackout mode. Press or 
turn an Encoder to reactivate the LCD 
display.
CONDITION: No input signal. Signal 
indicator is not fl ashing even though audio is 
applied, and the channel is ready.
POSSIBLE REASON
•  Input signal level is very low.
•  Another source is selected or routed.
CONDITION: Data indicator not fl ash-
ing, even though host computer 
software is active.
POSSIBLE REASON:
•  Cable between computer and amplifi er is bro ken 
or not connected.
Note: Data indicator fl ashes only when the amplifi er 
is polled for data, or is polled to see whether it is 
online.
CONDITION: Yellow LINK ACTIVITY indicator in 
Ethernet connector does not illuminate or fl ash.
POSSIBLE REASON:
•  Ethernet link is broken.
CONDITION: Computer does not communicate with the 
network devices.
POSSIBLE REASON:
•  Incorrect wiring. See Section 3.5 letter O on network wiring.
•  IP Addressing is not done correctly. Use the Network Troubleshooting 
Wizard in System Architect.
•  There is a short on the amplifi er output. First 
disconnect your speakers from the affected 
channel(s) one by one to determine if one of 
the loads is shorted.
CONDITION: COND indicator is off.
POSSIBLE REASON:
• There is only one conductor allowed per network system. This 
indicator is lit only when the amplifi er is the conductor.
•  Amplifi er is in blackout mode. Press or turn an Encoder to 
reactivate the LCD display.