GE Monogram ZDWT240PBS User Manual

Page of 3
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
ZDWT240PBS 
GE Monogram Wine Reserve with Liquid Crystal Privacy Glass
 
Dimensions and Installation Information
Specification Revised 12/06
120040
34-1/2"-35"
24" Min.
23-3/4" 
23-3/4" Min. 
25-1/2" 
Including  
Handle 
34-1/4"-
34-3/4"
23-3/4"
1-1/2" 
Locate Outlet 
9"  
Max.
10-1/2" 
A
Minimum to Wall  
110
°
110
° Door  
Swing
21-5/8"
23-5/8"
B
Minimum to Wall
90
°
90
° Door  
Swing
10"
Minimum to Wall
4"
Minimum to Wall
Installation Space 
The Monogram
®
 Wine Reserve may be installed beneath a 
countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2”-wide filler  
  strip or side panel may be required. The filler strip will act  
  as a spacer between the door case and adjacent cabinet  
  and will prevent interference with cabinet door swing. The 
  width of the opening must include filler panels.
Note: When installed, the door should project forward 1” of 
adjacent 24”-deep cabinets.
Location Requirements 
All Monogram Refrigeration Modules may be closed in on 
the top and sides as long as the front is unobstructed for air 
circulation and door swing.
• Do not install these products where the temperatures will  
  go  below 55°F (13°C) or above 90°F (32°C).
•  Do not install where they will be subject to direct sunlight,  
  heat or moisture.
• These products are not designed to be stacked one over  
  the other.
Side-by-Side Installation 
For a complete refreshment center, install a Monogram Wine 
Reserve and Beverage Center together.
• Products must operate from separate properly grounded  
  receptacles.
•  Do not install where they will be subject to direct sunlight,  
  heat or moisture. 
Door Swing Clearances 
All Monogram Refrigeration Modules are factory set for a 
110° door swing. When installed in a corner:
•  Allow the minimum door swing clearances shown.
•  The minimum clearance shown at 90° will allow full  
  extension of drawers and shelves. 
Dimensions and installation instructions are shown in inches.
Listed by 
Underwriters 
Laboratories
Electrical 
A  120V,  60Hz,  15  or  20  amp  power  supply  is  required.  
An  individual  properly  grounded  branch  circuit  or  circuit 
breaker  is  recommended.  Install  a  properly  grounded  
3-prong  electrical  recessed  into  the  back  wall  as  shown. 
Electrical must be located on rear wall as shown. 
Note: GFCI 
(ground fault circuit interrupter) is not recommended.