SGB Batch Blender with Mitsubishi Controller 
6-4 SGB Series Blender Menu Structure 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
“Recipe Book” Page 
Save the running recipe to the 
book 
¾
 
Delete a stored recipe 
¾
 
Load a stored recipe 
¾
 
Erase all stored recipes 
¾
 
Modify the product ID for a 
stored recipe 
¾
 
Return to the “Recipe” page
 
“Clean Out” Page 
¾
 
Empty the blender hopper(s) 
¾
 
Manually Operate the mixer, 
weigh hopper dump gate, and 
the slide gate below the mixer
¾
 
View and test all inputs and 
outputs on the blender 
¾
Return to the “Recipe” Page
“Inventory” Page 
¾
 
View the accumulated 
inventories 
¾
 
View batch time 
¾
 
View blender’s maximum 
capacity 
¾
 
View the average process 
rate 
¾
 
Return to the “Recipe” Page
 
“Setup” Page 
¾
  Login from the inventory page 
by hitting “Login” and entering 
in your password.  Then 
access setup by touching the 
Sterling Logo. 
Report Setup 
¾
 
Blender Number  
¾
 “Auto 
clear” 
option 
¾
 “Auto 
interval” 
setup 
¾
 
Auto start time  
 
Recipe Format 
¾
 
Percentage, Parts, or Quick 
Set 
¾
 Batch 
Size 
¾
 Inventory 
Shutdown 
¾
 
“Batch ready” mode 
¾
 
“Auto start” mode 
“Recipe” Page  
        (Start) 
¾
  Change Recipe Values by 
touching the number you 
wish to change 
¾
  Touch “Accept New Recipe” 
button after you’ve made 
the desired changes 
¾
  Start or stop the blender by 
touching the “Push to Start” 
or “Stop” button 
¾
  Access “Recipe Book” Page 
¾
  Access “Clean Out” Page 
¾
 Access 
“Inventory 
Page” 
¾
 Access 
“Setup” 
Page 
F940 “Config” 
¾
 
View software version 
¾
 
Access F940 “Config” setup to 
modify time settings
 
Units 
¾
  Blender data units (lbs. or 
kgs.) 
¾
  Target vs. actual data units 
(lbs. or kgs.) 
Calibration 
¾
 Scale 
Calibration 
¾
 
Direct Scale Readout 
¾
 Feeder 
Calibration 
Mixer and Dump Setup 
¾
 Mixing 
Time 
¾
 Remix 
Time 
¾
 Dump 
Time 
¾
 Dump 
Delay 
¾
 Dump 
Cycles 
¾
 
Mixer Dump Time 
¾
 Timed/Continuous 
Mixing 
Option 
Alarm Log 
¾
  View and clear the alarm log 
 
Alarm Setup 
¾
  “Stop/Continue” when out of 
material 
¾
  “Alarm/No Alarm” when out of 
material 
¾
  “Alarm Silence” delay 
User Interface Lock 
¾
  Lock the user interface to 
prevent others from making 
changes or viewing your 
blender.  Be sure to logout 