Twist Cap Plug Connected to Each Auger Motor (Auger Blender only) 
The cap plug must be turned counter-clockwise to loosen and the female end of the cord 
removed from the motor plug. This disables the motor from turning while the auger unit is 
being serviced or cleaned.  The motor cords are cut to length so they must be disconnected 
before the auger can be removed from the housing.  Disconnect plug before cleaning or 
servicing motors or augers. 
Figure 13:  Twist Cap Plug 
Motor 
Unscrew and remove plug 
from motor 
 
 
Electric Safety Interlock Switch (All Models) 
A unique electric safety switch is used to shut off power to the blender any time the mixer 
door is opened.  Do not alter or tamper with this switch in any way. 
Figure 14:  Electrical Safety Interlock Switch (Located on mixer door) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARNING!  Always disconnect and lockout all electrical power and pneumatic (i.e. compressed air) 
sources prior to servicing or cleaning the Slide Gate/Auger Blender. Failure to do so 
may result in serious injury. No one but the person who installed the lockout may 
remove it. 
Interlock Switch