5-2 Preventative 
Maintenance 
Our blenders need periodic maintenance to provide long dependable service. Check these 
elements regularly: 
•  Check functionality of safety circuit daily. 
•  Maintain proper air pressure and drain water from trap assembly on regulator – as 
required. 
•  Periodically lubricate slide gate rails. 
WARNING!  Always remove plug and disconnect power before servicing blender. 
 
 
 
WARNING!  Always read operating manual before operating or servicing blender. 
 
 
 
5-3 Corrective 
Maintenance 
Electrical 
This section is designed to give the operator an overview of the electrical system that controls 
the Slide Gate/Auger blending system. Since the blender’s control panel is a self-contained 
pluggable item, seldom will a maintenance person be required to enter the control panel. For 
purposes of understanding the system, it is advisable that the maintenance personnel be 
familiar with not only the internal workings of the control panel, but also with the input and 
output signals to the Slide Gate/Auger blender. 
This section includes the following:
 
•  Internal components of the control panel 
•  Input signal to the control panel 
•  Output signals from the control panel 
Internal Components of the Control Panel 
Note:  See Installation Packet supplied with unit for complete electrical schematics. 
This section describes the internal components of the Slide Gate/Auger blending system 
control panel. It is not the intent of this section to completely familiarize the reader with the 
details on industrial control panel construction or standards, but simply to familiarize the 
reader with the major components inside the control panel. 
The customer must supply 120/1/50 or 60 (or 220/1/50 or 60) via wires L1 & L2 (N). Please 
insure that the earth ground connection is properly connected to an established earth ground.   
“Power on” is indicated by a lighted on/off switch. 
“Slide gate below mixer” switch controls position of optional slide gate. 
“Safety Active” light displays status of safety interlock circuit.  Audible alarm horn alerts 
operator to blender fault.