7-2  Technical Specifications 
Annex B Information 
The following design information is provided for your reference: 
1.  No modifications are allowed to this equipment that could alter the CE compliance 
2.  Ambient temperature:   
40 degrees Celsius – Maximum (104 degrees Fahrenheit) 
3.  Humidity range:     
50% relative humidity 
4.  Altitude: 
 
 
  Sea 
level 
5.  Environment: 
 
 
Clean, dust-free and non-explosive 
6.  Radiation: 
  None 
7.  Vibration: 
  Minimal, 
i.e. 
machine 
mounting 
8.  Special installation requirements:  Clean, dry compressed air 1 cfm @ 60 psi (1.7 
m³/hr @ 4.14 bar) 
9.  Allowable voltage fluctuation: 
 
 
+/- 10% 
10. Allowable frequency fluctuation: 
Continuous 
+/- 1% 
 
  
   Intermittent 
+/- 
2% 
11. The addition of an auger feeder (RAM option) for regrind will increase the electrical 
supply requirements of a standard blender. 
12. Nominal supply voltage: 
120/1/60 or 220/1/50/60 (Verify on serial number tag) 
13. Earth ground type: 
TN (system has one point directly earthed through a 
protective conductor) 
14. Power supply should include a neutral power connection. 
15. Over-current protection is supplied in the blender, but additional protection should be 
supplied by the user. 
16. The plug on the power cord serves as the electrical disconnect device. 
17. Unit is not equipped with three-phase motors. 
18. N/A 
19. Blender is not equipped with local lighting. 
20. Functional identification 
21. Blender is equipped with a CE mark 
22. Blender is supplied with an operating manual in the language of the destination country. 
23. Cable support may be required for power cord, depending on final installation. 
24. No one is required to be in the interior of the electrical enclosure during the normal 
operation of the unit.  Only skilled electricians should be inside the enclosure for 
maintenance. 
25. Doors can be opened with a screwdriver, but no keys are required. 
26. Two-hand control is not required or provided. 
27. All blenders should be moved around and set in a place with a lift truck or equivalent.