Chapter 8:  Addendum   
8-1 Service 
Supervisor 
Information 
Note:  This section of the manual should not be used by untrained personnel – 
blender controller and/or program can be compromised! 
Note:  Hidden, programmable features and hidden menu pages should not be made 
available to floor operators. These pages include the Service Supervisor 
Information addendum located in this section. Unauthorized changes to these 
factory settings by inexperienced operators may prevent the unit from 
operating properly, and may void part or all of the warranty. 
Programmable Settings 
The Slide Gate/Auger blender software program has been designed to allow some 
customizing to achieve certain desired operating parameters. The following is a listing of the 
selections that are “field” programmable, followed by the procedure for doing so. 
This menu is accessed by pressing the manufacturer’s icon when in the “Setup” Directory 
Screen menu. 
 
 
 
 
 
 
Enter the long password “3145348” and press “Enter”. The factory setup section displays the 
“Engineering Only” screen.  The screen similar to that shown below should be displayed and 
use the keystrokes described herein to change or toggle the parameters. 
 
 
 
 
 
 
 
 
 
 
Factory Setup Menu (Available Selections) 
Metering Test Screen 
This screen is useful in both R & D and development purposes when testing the metering 
performance of each feeder.   The user can perform a “Single Meter by Weight” to evaluate 
the mechanical standard deviation of the gate or auger.  This test meters for the calculated 
time based off the target weight entered on this screen.  The blender does not retry or adjust 
the time of the meter to reach the target, but instead always meters for the same amount of 
Touch this icon and 
enter in the Service 
Password to access the 
Engineering Only 
Directory 
Go back to 
Setup 
Directory